The Chartered institution of
Building Services Engineers Product Data Template |
Tank | |||
Template Category | Tank | |||
Template Version | v1 | |||
Category Description | An open or closed container used for storing a fluid at ambient pressure and from which it can be supplied to the fluid distribution system. There are | |||
Classification | Pr_60_50_96 | |||
Classification System | Uniclass2015 | |||
Suitability for Use | Approved | |||
Template Custodian | CIBSE | |||
Information Category | Parameter Name | Value | Units | Notes |
Manufacturer Data | ||||
COBie Data | Manufacturer | Text | This is a COBie field, other fields will be required in final PDTs |
|
Specifications | Manufacturer Website | URL | ||
Specifications | Product Range | Text | ||
Specifications | Product Model Number | Text | Or Code |
|
Specifications | CE Mark | Text | Number, Yes, No |
|
Specifications | Product Literature | URL | ||
COBie Data | Features | Text | This is a COBie field, other fields will be required in final PDTs |
|
Construction Data | ||||
Specifications | Storage Type | Enumeration | ||
Specifications | Connection Type | Text | e.g. flanged, screwed etc. |
|
Specifications | Function | Enumeration | ||
Specifications | Pattern Type | Enumeration | Defines the types of pattern (or shape of) a tank. |
|
Specifications | End Shape Type | Enumeration | Defines the end shapes of preformed tanks. For a vertical cylinder, the first value is the base and the second is the top. For a spherical tank, the value UNSET should be used |
|
Specifications | First Curvature Radius | mm | FirstCurvatureRadius is defined as the base or left side radius of curvature value. |
|
Specifications | Second Curvature Radius | mm | SecondCurvatureRadius is defined as the top or right side radius of curvature value. |
|
Specifications | Tank Composition | Enumeration | Defines element composition where. COMPLEX: A set of elementary units aggregated together. ELEMENT: A single elementary unit that may exist of itself or as an aggregation of partial units. PARTIAL: A partial elementary unit. |
|
Specifications | Number Of Sections | Number | Number of sections used in the construction of the tank. Default is 1. (Note: All sections assumed to be the same size). |
|
Specifications | Externally Flanged | Y/N | ||
COBie Data | Material | Text | This is a COBie field, other fields will be required in final PDTs |
|
Specifications | Access Type | Enumeration | ||
Specifications | Structural Internal Division | Y/N | ||
Specifications | Has External Ladder | Y/N | ||
Specifications | Has Internal Ladder | Y/N | ||
Specifications | Has Visual Indicator | Y/N | Visual indicator or contents gauge |
|
Specifications | Valve Housing | Text | ||
Specifications | Vortex Inhibitor | Y/N | ||
Specifications | Integral Pump | Y/N | ||
Specifications | Immersion Heater | Y/N | ||
Specifications | Air Gap Type | Enumeration | ||
Specifications | Factory Insulation | Y/N | ||
Dimensional Data | ||||
Specifications | Overall Length | mm | Or Diameter. Minimum and maximum lengths available |
|
Specifications | Overall Width | mm | Minimum and maximum widths available |
|
Specifications | Overall Height | mm | Minimum and maximum heights available |
|
Specifications | Gross Weight | kg | Equates to Operating Weight |
|
Specifications | Shipping Weight | kg | Equates to dry weight of unit plus packaging allowance |
|
Specifications | Operating Weight | kg | ||
Specifications | Inlet Connection Size | Range:Minimum.,,Maximum. |
||
Specifications | Outlet Connection Size | Range:Minimum.,,Maximum. |
||
Specifications | Warning Pipe Size | mm | Range:Minimum.,,Maximum. |
|
Specifications | Overflow Pipe Size | mm | Range:Minimum.,,Maximum. |
|
Specifications | Drain Size | Range:Minimum.,,Maximum. |
||
Specifications | Drain Location | Range:Minimum.,,Maximum. |
||
Specifications | Access Clearance Top | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Bottom | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Left | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Right | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Front | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Rear | mm | Access required for maintenance of this item |
|
Specifications | Access Ball Valve Housing | mm | ||
Performance Data | ||||
Specifications | Operating Pressure | kPa | Range:Minimum.,,Maximum. |
|
Specifications | Operating Temperature | DegC | Range:Minimum.,,Maximum. |
|
Specifications | Maximum Inlet Pressure | kPa | ||
Specifications | Nominal Capacity | litres | ||
Specifications | Effective Capacity | litres | ||
Electrical Data | ||||
Specifications | Power Source | Text | e.g. Integral battery, System-powered, Other, UserDefined |
|
Specifications | Voltage | V | ||
Specifications | Supply Phase | Number | 1, 3 |
|
Specifications | Incoming Supply Electrical Frequency | Hertz | e.g. N/A, DC, 50,60, Other, UserDefined |
|
Specifications | Integral Pump Motor Enclosure Rating | Text | IP numbers |
|
Specifications | Integral Pump Motor Type | Text | ||
Specifications | Integral Pump Number of Poles | Number | 1,3 |
|
Specifications | Integral Pump Motor Efficiency Class CEMEP | Text | ||
Specifications | Integral Pump Motor Rating | kW | Range:Minimum.,,Maximum. |
|
Specifications | Integral Pump Starting Method | Text | DoL,StarDelta, Soft |
|
Specifications | Immersion Heater Rating | kW | Range:Minimum.,,Maximum. |
|
Application Data | ||||
Specifications | Reference Standard | Text | ||
Specifications | Configuration | Text | e.g. Self-standing, Fire Alarm System supported (loop), Other, UserDefined |
|
Controls | ||||
Specifications | High Level Alarm Switch | Y/N | ||
Specifications | Mid Level Alarm Switch | Y/N | ||
Specifications | Low Level Alarm Switch | Y/N | ||
Specifications | Pump 1 Start Switch | Y/N | ||
Specifications | Pump 2 Start Switch | Y/N | ||
Specifications | Pump Stop Switch | Y/N | ||
Specifications | BMS Links | Y/N | ||
Specifications | Temperature sensor | Y/N | ||
Specifications | Contents Gauge | Y/N | ||
Sustainability | ||||
Sustainable Material BREEAM etc | Embodied Carbon | kgCO2e | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Life Cycle Analysis | Number | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Location of Manufacturer | GridRef | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Green Guide for Specification | Enumeration | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Environmental Product Declaration | Text | 3rd Party Verification |
|
Sustainable Material BREEAM etc | Responsible Sourcing of Materials | Enumeration | Awaiting Industry Standard |
|
Sustainable Material ETL | Energy Technology List | URL | Hyperlink to ETL webpage for product |
|
Sustainable Material LEED v.4 | Responsible Extraction of Materials | Text | Awaiting Industry Standard |
|
Sustainable Material LEED v.4 | Material Ingredient Reporting | Text | Awaiting Industry Standard |
|
Operations & Maintenance | ||||
Facilities/Asset Management | Operation and Maintenance Manual | URL | Hyperlink to Manufacturer O&M Data |
|
Facilities/Asset Management | Daily | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | Weekly | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | Monthly | Text | Maintenance tasks or SFG20 codes. If Not Applicable Mark '0' |
|
Facilities/Asset Management | Quarterly | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | 6 Monthly | Text | ||
Facilities/Asset Management | Annually | Text | ||
Facilities/Asset Management | Bespoke Timeframe | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | Maintenance Required 0 to 300hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 301 to 600hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 601 to 1000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 1001 to 2000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 2001 to 4000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 4001 to 8000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 8001 to 12000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Expected Life | Years | ||
Facilities/Asset Management | Warranty ID | Text | ||
This schedule is the property of CIBSE although it can be freely used in the ways described, and completed with data specific to particular products. It is important that the Categories and Parameters given on the form are not changed. It is also important that where units of measurement are defined on the form that these too are followed. Any comment or suggestion on their revision should be addressed to pdt@cibse.org |
||||
©CIBSE 2015
©The Chartered Institution of Building Services Engineers www.cibse.org
|