The Chartered institution of
Building Services Engineers Product Data Template |
Fan Convector Unit | |||
Template Category | Fan Convector Unit | |||
Template Version | v1 | |||
Category Description | Device for heating a space, consisting of heating coil, fan and casing | |||
Classification | Pr_70_60_36_30 | |||
Classification System | Uniclass2015 | |||
Suitability for Use | Approved | |||
Template Custodian | CIBSE | |||
Information Category | Parameter Name | Value | Units | Notes |
Manufacturer Data | ||||
COBie Data | Manufacturer | Text | This is a COBie field, other fields will be required in final PDTs |
|
Specifications | Manufacturer Website | URL | ||
Specifications | Product Range | Text | ||
Specifications | Product Model Number | Text | Or Code |
|
Specifications | CE Mark | Text | Number, Yes, No |
|
Specifications | Product Literature | URL | ||
COBie Data | Features | Text | This is a COBie field, other fields will be required in final PDTs |
|
Construction Data | ||||
Specifications | Configuration | Enumeration | ||
Specifications | Final Location | Enumeration | ||
Specifications | Airflow Type | Enumeration | ||
Specifications | Mounting | Enumeration | State how product is mounted |
|
Specifications | Inlet Position | Enumeration | ||
Specifications | Outlet Position | Enumeration | ||
Specifications | Heating Medium | Enumeration | ||
Specifications | Fan Type | Enumeration | Axial or Radial |
|
Specifications | Motor Type | Enumeration | ACDC, AC, DC or EC |
|
Specifications | Inlet Filter | Y/N | ||
Specifications | Fluid Connection Type | Enumeration | ||
Dimensional Data | ||||
Specifications | Overall Length | mm | Or Diameter. Minimum and maximum lengths available |
|
Specifications | Overall Width | mm | Minimum and maximum widths available |
|
Specifications | Overall Height | mm | Minimum and maximum heights available |
|
Specifications | Gross Weight | kg | Equates to Operating Weight |
|
Specifications | Shipping Weight | kg | Equates to dry weight of unit plus packaging allowance |
|
Specifications | Access Clearance Top | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Bottom | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Left | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Right | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Front | mm | Access required for maintenance of this item |
|
Specifications | Access Clearance Rear | mm | Access required for maintenance of this item |
|
Specifications | Air Inlet Width | mm | Width of the Inlet connection |
|
Specifications | Air Inlet Height | mm | Height of the Inlet connection |
|
Specifications | Air Outlet Width | mm | Width of the Outlet connection |
|
Specifications | Air Outlet Height | mm | Height of the Outlet connection |
|
Specifications | Pipe Connection Diameter | |||
Performance Data | ||||
Specifications | Heating Output | kW | ||
Specifications | Heating Medium Temperature | DegC | F/R for Water, working temperature |
|
Specifications | Heating Medium Pressure | kPa | F/R for Water, working pressure |
|
Specifications | Reference Space Temperature | DegC | ||
Specifications | Nominal Air Volume Flowrate | l/s | litres per second |
|
Specifications | Nominal Fluid Volume Flowrate | kg/s | Only for Water Coils |
|
Specifications | Fluid Side Pressure Drop | kPa | ||
Specifications | Fluid Volume | litres | ||
Specifications | Fluid Maximum Working Pressure | kPa | ||
Specifications | Test Pressure | kPa | ||
Electrical Data | ||||
Specifications | Incoming Supply Voltage | V | ||
Specifications | Incoming Supply Phases | Number | 1,3 |
|
Specifications | Incoming Supply Frequency | Hertz | 50, 60 |
|
Specifications | Maximum Supply Current | A | ||
Specifications | Maximum Power Consumption | W | ||
Specifications | Nominal Specific Fan Power | kW | ||
Application Data | ||||
Specifications | Reference Standard | Text | ||
Controls | ||||
Specifications | BMS Links | Y/N | ||
Specifications | In-Built Temperature Control | Y/N | On/Off, Change Speed. Includes Sensor and Actuator |
|
Specifications | Remote Temperature Control | Y/N | On/Off, Change Speed, Tamper Proof. Includes Sensor and Actuator |
|
Specifications | Low Water Temperature Thermostat | Y/N | ||
Specifications | Internal Switches | Y/N | On/Off, Change Speed, Summer/Winter |
|
Specifications | Case Mounted Switches | Y/N | On/Off, Change Speed, Summer/Winter |
|
Specifications | 2 Port Water valves | Y/N | ||
Specifications | 3 Port Water valves | Y/N | ||
Specifications | Remote Switches | Y/N | On/Off, Change Speed, Summer/Winter |
|
Specifications | Wireless Controllers | Y/N | ||
Accessories | ||||
Specifications | Lockable Access Panel | Y/N | ||
Specifications | Tamper Proof Access Panel | Y/N | ||
Specifications | Plinth | Y/N | ||
Specifications | Loose Grilles | Y/N | ||
Specifications | Wall Mounting Stiffeners | Y/N | ||
Specifications | Rounded End Panels | Y/N | ||
Specifications | Isolating Valves | Y/N | ||
Specifications | Flexible Connectors | Y/N | ||
Specifications | Special Heat Exchanger | Y/N | ||
Sustainability | ||||
Sustainable Material BREEAM etc | Embodied Carbon | kgCO2e | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Life Cycle Analysis | Number | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Location of Manufacturer | GridRef | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Green Guide for Specification | Enumeration | Awaiting Industry Standard |
|
Sustainable Material BREEAM etc | Environmental Product Declaration | Text | 3rd Party Verification |
|
Sustainable Material BREEAM etc | Responsible Sourcing of Materials | Enumeration | Awaiting Industry Standard |
|
Sustainable Material ETL | Energy Technology List | URL | Hyperlink to ETL webpage for product |
|
Sustainable Material LEED v.4 | Responsible Extraction of Materials | Text | Awaiting Industry Standard |
|
Sustainable Material LEED v.4 | Material Ingredient Reporting | Text | Awaiting Industry Standard |
|
Operations & Maintenance | ||||
Facilities/Asset Management | O&M Manual | URL | Hyperlink to ETL webpage for product |
|
Facilities/Asset Management | Hourly | Text | Maintenance tasked required at this frequency. |
|
Facilities/Asset Management | Daily | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | Weekly | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | Monthly | Text | Maintenance tasks or SFG20 codes. If Not Applicable Mark '0' |
|
Facilities/Asset Management | Quarterly | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | 6 Monthly | Text | ||
Facilities/Asset Management | Annually | Text | ||
Facilities/Asset Management | Bespoke Timeframe | Text | Maintenance tasks or SFG20 codes |
|
Facilities/Asset Management | Maintenance Required 0 to 300hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 301 to 600hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 601 to 1000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 1001 to 2000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 2001 to 4000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 4001 to 8000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Maintenance Required 8001 to 12000hrs | Text | Maintenance tasks required during this time frame |
|
Facilities/Asset Management | Expected Life | Years | ||
Facilities/Asset Management | Warranty ID | Text | ||
This schedule is the property of CIBSE although it can be freely used in the ways described, and completed with data specific to particular products. It is important that the Categories and Parameters given on the form are not changed. It is also important that where units of measurement are defined on the form that these too are followed. Any comment or suggestion on their revision should be addressed to pdt@cibse.org |
||||
©CIBSE 2015
©The Chartered Institution of Building Services Engineers www.cibse.org
|